The titanLIGHT™ uses patent pending air vents below the flame to reduce wind disturbance along with a flame guard that is designed to provide maximum protection against wind gust. A small screw-off cap on the bottom of the lighter body is used to both refill with lighter fluid and to service the wick. The flame guard can also be removed without tools by press the small brass pin through while holding the flame guard down.
To refill, unscrew the bottom cap and be careful not to overfill (Approx. 3mL). To replace the flint, simply press the small brass pin through while holding the flame guard down then pull off the flame guard to access the flint and spring. Watch for small spring and remainder of flint to fall out.